M. Hominis-Q Real-Time PCR Kit

Qualitative Detection of Mycoplasma Hominis DNA

The M. Hominis-Q Real-Time PCR Kit is an in vitro diagnostic (IVD) molecular test basedon real-time PCR technology. It is designed for the qualitative detection of MycoplasmaHominis (MH) DNA in urine samples or swabs from the vagina, cervix, or urethra. This test enables rapid and accurate detection of M. hominis through a standardized real-time PCR workflow, allowing for timely diagnosis and proper clinical management of M.hominis-associated infections.

Product Overview


The M. Hominis-Q Real-Time PCR Kit uses real-time PCR technology for the qualitativedetection of M. hominis in urine samples or swabs from the vagina, cervix, or urethra. The kit integrates seamlessly with the OnePCR Ultra-Fast POC Rapid RT-PCR System,which automates DNA extraction and the real-time PCR analysis.

The kit detects:

  • Mycoplasma Hominis (MH) specific DNA
  • Internal Control (IC) for assay validation and quality assurance

This kit contains specific primers and fluorescent probes that target M. hominis. Byusing probes linked to different dyes, the system allows for parallel qualitative detectionof M. hominis and the internal control.

Mycoplasma Hominis

Why M. Hominis Testing Matters


M. hominis is a type of bacteria belonging to the Mycoplasma genus. It is commonlyfound in the human genital tract and can exist harmlessly as part of the normalmicrobiota. However, in certain conditions, it can become harmful and lead to variousinfections, especially in those with weakened immune systems or individuals who havehad invasive medical procedures. The bacterium can invade the urogenital tract andother tissues, causing inflammation, pain, and potential long-term complications.

Molecular methods like real-time PCR enable rapid, specific, and sensitive detection ofM. Hominis infections, which improves diagnostic accuracy and allows for prompttreatment. The M. Hominis-Q Real-Time PCR Kit helps laboratories to:

Targets Detected


Qualitative Targets
  • Mycoplasma Hominis DNA
  • Internal Control (IC)
Internal Control
  • Internal Control (IC)
    This ensures successful DNA extraction, assay integrity, sample adequacy, and reliableamplification for every sample.

Applications


The kit is ideal for clinical molecular laboratories performing:

M. hominis Real-Time PCR Kit
  • M. hominis molecular detection
  • Early molecular diagnosis of M. hominis infection
  • Routine M. hominis molecular testing
  • Confirmation of suspected M. hominis-associated infections (e.g. PID, bacterialvaginosis, UTIs)
  • Integration into infectious disease molecular diagnostic workflows

Key Features & Benefits


Automated Sample-to-Result Workflow

Integrated with the OnePCR Ultra-Fast POCRapid RT-PCR System for automated DNA extraction, amplification, and resultinterpretation with minimal hands-on time.

Sensitive and Specific Detection

Uses target-specific primers and fluorescent probe-based chemistry for highly sensitive and specific detection of M. hominis DNA.

Parallel Qualitative Detection

Employs probes linked to different dyes, allowingsimultaneous detection of the M. hominis target and the internal control within a singlereaction.

Built-in Internal Control for Quality Assurance

The built-in Internal Control verifiessuccessful DNA extraction, sample quality, and assay performance, providingconfidence in all reported results.

Optimized for Routine Clinical Testing

Optimized for Routine Clinical Testing: Designed for rapid and reliable moleculardiagnosis in clinical laboratories conducting routine infectious disease testing.

Sample Types & Reporting Output


Sample Types

Validated for use with:

  • Urine samples
  • Swabs from the vagina
  • Swabs from the cervix
  • Swabs from the urethra
Reporting Output

The test provides clear lab results, including:

  • Positive / Negative interpretation
  • Ct values
  • Amplification curves
  • Internal Control status
  • Result export options (USB or Bluetooth)

Compatible System


OnePCR: OnePCR POC Rapid RT-PCR System (Genes 2Me Private Limited)

This system is designed for a fully automated workflow that combines sample DNAextraction and real-time PCR amplification.

ONEPCR Automated Testing Workflow
  • Collect a urine sample or a swab from the vagina, cervix, or urethra.
  • Load 200 μL of the sample into well 'A' (marked 'Sample') of Cartridge-1.
  • Reconstitute Cartridge-2 by adding and mixing 10 μL Reconstitution Buffer intoposition A, and attach the tube adaptor.
  • Insert Cartridge-1 and Cartridge-2 into the OnePCR POC Rapid RT-PCR System.
  • The system runs fully automated DNA extraction and real-time PCR amplification.
  • Results are displayed with Ct values, amplification curves, and positive/negativeinterpretation.

Storage & Stability


Ordering Information


Commercial Name Old Cat No. New Cat No. Pack Size
M. Hominis-Q Real-TimePCR Kit G2M707221R 24 Tests

Why Choose the M. Hominis-Q Real-Time PCR Kit?


If your lab needs a reliable molecular assay for rapid detection of Mycoplasma HominisDNA, the M. Hominis-Q Real-Time PCR Kit offers:

  • automated DNA extraction and real-time PCR workflow
  • highly sensitive and specific probe-based detection
  • built-in Internal Control for assay validation
  • dependable and accurate diagnostic performance
  • minimal hands-on time with an integrated sample-to-result workflow
  • suitability for routine M. hominis molecular diagnostics
  • smooth integration into infectious disease molecular testing workflows

Product Enquiry Form


Other Products


Since its inception in 2016, Genes2me has been constantly striving towards setting a benchmark in the diagnostics space by introducing premium quality (Made in India) diagnostic kits which are CE-IVD, ISO-13485:2016, and ISO 9001:2015 certified, assuring our clients of unparalleled quality and compliance with international standards.